{"product_id":"hpc-fire-commercial-emergency-stop-120vac-or-24-vac","title":"HPC Fire Commercial Emergency Stop - 120VAC or 24 VAC","description":"\u003ch1\u003eHPC Fire Commercial Emergency Stop - 120VAC or 24 VAC\u003c\/h1\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003eDescription\u003c\/h2\u003e\n\u003cp\u003eEvery fire feature that operates with an electronic ignition system carries one question that never fully goes away: what happens if something goes wrong and you need it off right now? For residential use, the answer is usually the wall switch or the remote. For commercial settings -- hotels, restaurants, rooftop bars, hospitality venues, multi-residential properties, and anywhere the public has proximity to a live fire feature -- that answer needs to be faster, more reliable, and controlled by someone with authority. That is exactly what the HPC Commercial Emergency Stop is built to do.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eThe 311-ESTOP-3 is a push-button emergency shut-off device designed specifically for commercial applications of HPC's Evolution 360 and Electronic Ignition (EI \/ HWI) fire pit systems. It is installed on the 120VAC or 24VAC electrical line and, when activated, immediately stops the flow of current to the burner -- shutting down up to 3 separate circuits plus one additional fail-safe function simultaneously. The result is a complete, near-instant shutdown of the fire feature with a single button press.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eWhat makes the 311-ESTOP-3 suited for commercial environments specifically is the keyed reset. Once the push button is activated, the system does not restart on its own and cannot be restarted by simply pressing the button again. A physical key is required to release and reset the switch, which means a supervisor, manager, or authorized staff member must be physically present and deliberately restart the system. In a hotel courtyard, a rooftop lounge, or a restaurant patio where the fire feature is in a public area, this is not just a convenience -- it is a meaningful operational safety control.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eThe device is housed in a rugged, compact enclosure rated IP65 -- fully protected against dust ingress and low-pressure water spray from any direction, making it suitable for permanent outdoor installation in rain-exposed locations. It measures 2.8 by 2.8 by 4 inches and is rated for 600VA at 10A, handling the electrical load of commercial fire pit applications without issue. Compatible with both 120VAC and 24VAC system configurations.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eThe replacement key is available separately and should be kept on hand for facilities where the E-Stop is used regularly.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eProducts typically ship in 1 to 2 business days from HPC's warehouses in Las Vegas, NV and Dayton, OH.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eBackyard Prime Living is a certified authorized reseller of HPC Fire. Every purchase includes full manufacturer warranty support and our commitment to extraordinary customer care.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003eFeatures\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eDesigned for Commercial Fire Pit Installations -- The 311-ESTOP-3 is purpose-built for commercial applications of HPC Evolution 360 and Electronic Ignition (EI \/ HWI) fire pit systems in hotels, restaurants, hospitality venues, rooftop bars, multi-residential properties, and any high-traffic public outdoor setting with a live fire feature.\u003c\/li\u003e\n\u003cli\u003eInstant Push-Button Emergency Shutdown -- A single button press immediately stops the flow of current to the connected HPC burner system, shutting down the fire feature without requiring access to the main ignition controls or remote.\u003c\/li\u003e\n\u003cli\u003eShuts Off Up to 3 Circuits Plus One Fail-Safe Function -- The E-Stop simultaneously controls up to 3 separate circuits and one additional fail-safe output, providing comprehensive shutdown coverage for the entire fire feature system in a single action.\u003c\/li\u003e\n\u003cli\u003eKeyed Reset for Supervisor Control -- Once activated, the push button requires a physical key release and reset before the system can be restarted. This ensures that only authorized personnel -- a supervisor, manager, or designated staff member -- can bring the fire feature back into operation after an emergency shutdown. The system will not restart on its own.\u003c\/li\u003e\n\u003cli\u003eInstalled on the 120V or 24V Electrical Line -- The 311-ESTOP-3 is wired directly into the 120VAC or 24VAC supply line feeding the HPC burner. When triggered, it cuts the electrical supply to the ignition system, stopping gas flow through the electronic valve.\u003c\/li\u003e\n\u003cli\u003eCompatible with HPC Evolution 360 and EI \/ HWI Systems -- Specifically designed and validated for use with HPC's Evolution 360 fire pit control systems and all standard Electronic Ignition (EI) and Hot Wire Ignition (HWI) configurations.\u003c\/li\u003e\n\u003cli\u003eIP65 Weather-Rated Enclosure -- Rated IP65 for full protection against dust ingress and resistance to low-pressure water spray from all directions. Suitable for permanent outdoor installation in rain-exposed environments.\u003c\/li\u003e\n\u003cli\u003eCompact Form Factor -- Measures 2.8 in x 2.8 in x 4 in. Small enough to mount discreetly in a wall, post, or enclosure near the fire feature without requiring a large housing or dedicated electrical panel space.\u003c\/li\u003e\n\u003cli\u003eHigh Electrical Rating -- Rated 600VA at 10A, providing reliable performance across the full load range of commercial HPC fire pit systems.\u003c\/li\u003e\n\u003cli\u003eThree-Circuit Wiring Configuration -- The wiring diagram (from the official HPC spec sheet) shows three independent hot wire in\/out pairs (Options 1, 2, and 3) wired in parallel from the 120VAC or 24VAC supply, allowing control of multiple circuits from a single E-Stop installation.\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003eWhat's Included\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eINCLUDED IN THE BOX:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eHPC 311-ESTOP-3 Commercial Emergency Stop unit\u003c\/li\u003e\n\u003cli\u003eKeyed reset key (for supervisor release and restart)\u003c\/li\u003e\n\u003cli\u003eMounting hardware\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eNOT INCLUDED \/ SOLD SEPARATELY:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eE-Stop Replacement Key (available separately -- part of the E-Stop \/ Replacement Key option on the product listing; MSRP approximately $65)\u003c\/li\u003e\n\u003cli\u003eElectrical wiring and conduit (all wiring must be supplied and installed by a certified licensed electrician)\u003c\/li\u003e\n\u003cli\u003eCompatible HPC Electronic Ignition System (Evolution 360, EI, or HWI -- sold separately) - Junction box or enclosure for mounting (if surface or post-mount installation is required)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eINSTALLATION NOTE: The 311-ESTOP-3 is installed on the 120VAC or 24VAC electrical line by a certified licensed electrician. All wiring must comply with local electrical codes. See the official HPC wiring diagram for the 3-circuit wiring schematic showing Hot Wire In \/ Hot Wire Out for Options 1, 2, and 3. Consult HPC Fire directly for any installation questions: (937) 436-9800 or information@hpcfire.com.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eManufacturer:\u003c\/strong\u003e HPC Fire (Hearth Products Controls)\u003cbr\u003e\u003cstrong\u003eModel \/ Part Number:\u003c\/strong\u003e 311-ESTOP-3\u003cbr\u003e\u003cstrong\u003eProduct Type:\u003c\/strong\u003e Commercial Emergency Stop Push Button\u003cbr\u003e\u003cstrong\u003eCategory:\u003c\/strong\u003e Fire Pit Safety Accessory\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDIMENSIONS:\u003c\/strong\u003e\u003cbr\u003eSize: 2.8 in x 2.8 in x 4 in\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eELECTRICAL RATINGS:\u003c\/strong\u003e\u003cbr\u003eVoltage Compatibility: 120VAC or 24VAC (or 12VAC per product title)\u003cbr\u003eElectrical Rating: 600VA, 10A\u003cbr\u003eWiring Configuration: 3 independent hot wire circuits (Option 1, 2, 3) plus 1 fail-safe function\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eINGRESS PROTECTION:\u003c\/strong\u003e\u003cbr\u003eIP Rating: IP65 -- fully dustproof; protected against low-pressure water spray from all directions\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOPERATION:\u003c\/strong\u003e\u003cbr\u003eActivation: Push button -- single press immediately cuts power to connected circuits\u003cbr\u003eReset: Keyed release\/reset required; system will not restart without key\u003cbr\u003eRestart Authority: Key holder only (supervisor \/ authorized personnel)\u003cbr\u003eNumber of Circuits Controlled: Up to 3 circuits plus 1 fail-safe function\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCOMPATIBILITY:\u003c\/strong\u003e\u003cbr\u003eSystems: HPC Evolution 360 fire pit control systems; HPC Electronic Ignition (EI) systems; HPC Hot Wire Ignition (HWI) systems\u003cbr\u003eInstallation Point: Wired into 120VAC or 24VAC supply line to the HPC burner\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSHIPPING:\u003c\/strong\u003e\u003cbr\u003eShips From: Las Vegas, NV and Dayton, OH (HPC warehouses)\u003cbr\u003eLead Time: Typically 1 to 2 business days\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWARRANTY:\u003c\/strong\u003e\u003cbr\u003eCoverage: HPC Fire standard warranty applies; contact HPC for specific coverage details\u003cbr\u003eWarranty Page: https:\/\/hpcfire.com\/warranty-information\/\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003eManuals \/ Downloads\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan style=\"color: rgb(0, 170, 255);\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0752\/7353\/5673\/files\/HPC_311-E-stop_info_sheet.pdf?v=1780312646\" title=\"HPC Fire Commercial Emergency Stop Button Information Sheet\" style=\"color: rgb(0, 170, 255);\" rel=\"noopener\" target=\"_blank\"\u003eHPC E-Stop Information Sheet\u003c\/a\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e","brand":"HPC Fire","offers":[{"title":"Default Title","offer_id":47314670682297,"sku":"311-ESTOP-3","price":501.6,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0752\/7353\/5673\/files\/311-ESTOP-nokey.jpg?v=1780313463","url":"https:\/\/backyardprimeliving.com\/products\/hpc-fire-commercial-emergency-stop-120vac-or-24-vac","provider":"Backyard Prime Living","version":"1.0","type":"link"}