HPC Fire Commercial Emergency Stop - 120VAC or 24 VAC
Authorized Reseller — Shop With Confidence
Backyard Prime Living is a certified authorized reseller of all brands we carry, including Golden Designs, HPC Fire, KoKoMo Grills, Leisurecraft, Scandia, Sequoia, The Outdoor Plus, Mande Spa and Videl USA. Every purchase includes full manufacturer warranty support and is backed by our commitment to extraordinary customer care.
Choose options


HPC Fire Commercial Emergency Stop - 120VAC or 24 VAC
Description
Every fire feature that operates with an electronic ignition system carries one question that never fully goes away: what happens if something goes wrong and you need it off right now? For residential use, the answer is usually the wall switch or the remote. For commercial settings -- hotels, restaurants, rooftop bars, hospitality venues, multi-residential properties, and anywhere the public has proximity to a live fire feature -- that answer needs to be faster, more reliable, and controlled by someone with authority. That is exactly what the HPC Commercial Emergency Stop is built to do.
The 311-ESTOP-3 is a push-button emergency shut-off device designed specifically for commercial applications of HPC's Evolution 360 and Electronic Ignition (EI / HWI) fire pit systems. It is installed on the 120VAC or 24VAC electrical line and, when activated, immediately stops the flow of current to the burner -- shutting down up to 3 separate circuits plus one additional fail-safe function simultaneously. The result is a complete, near-instant shutdown of the fire feature with a single button press.
What makes the 311-ESTOP-3 suited for commercial environments specifically is the keyed reset. Once the push button is activated, the system does not restart on its own and cannot be restarted by simply pressing the button again. A physical key is required to release and reset the switch, which means a supervisor, manager, or authorized staff member must be physically present and deliberately restart the system. In a hotel courtyard, a rooftop lounge, or a restaurant patio where the fire feature is in a public area, this is not just a convenience -- it is a meaningful operational safety control.
The device is housed in a rugged, compact enclosure rated IP65 -- fully protected against dust ingress and low-pressure water spray from any direction, making it suitable for permanent outdoor installation in rain-exposed locations. It measures 2.8 by 2.8 by 4 inches and is rated for 600VA at 10A, handling the electrical load of commercial fire pit applications without issue. Compatible with both 120VAC and 24VAC system configurations.
The replacement key is available separately and should be kept on hand for facilities where the E-Stop is used regularly.
Products typically ship in 1 to 2 business days from HPC's warehouses in Las Vegas, NV and Dayton, OH.
Backyard Prime Living is a certified authorized reseller of HPC Fire. Every purchase includes full manufacturer warranty support and our commitment to extraordinary customer care.
Features
- Designed for Commercial Fire Pit Installations -- The 311-ESTOP-3 is purpose-built for commercial applications of HPC Evolution 360 and Electronic Ignition (EI / HWI) fire pit systems in hotels, restaurants, hospitality venues, rooftop bars, multi-residential properties, and any high-traffic public outdoor setting with a live fire feature.
- Instant Push-Button Emergency Shutdown -- A single button press immediately stops the flow of current to the connected HPC burner system, shutting down the fire feature without requiring access to the main ignition controls or remote.
- Shuts Off Up to 3 Circuits Plus One Fail-Safe Function -- The E-Stop simultaneously controls up to 3 separate circuits and one additional fail-safe output, providing comprehensive shutdown coverage for the entire fire feature system in a single action.
- Keyed Reset for Supervisor Control -- Once activated, the push button requires a physical key release and reset before the system can be restarted. This ensures that only authorized personnel -- a supervisor, manager, or designated staff member -- can bring the fire feature back into operation after an emergency shutdown. The system will not restart on its own.
- Installed on the 120V or 24V Electrical Line -- The 311-ESTOP-3 is wired directly into the 120VAC or 24VAC supply line feeding the HPC burner. When triggered, it cuts the electrical supply to the ignition system, stopping gas flow through the electronic valve.
- Compatible with HPC Evolution 360 and EI / HWI Systems -- Specifically designed and validated for use with HPC's Evolution 360 fire pit control systems and all standard Electronic Ignition (EI) and Hot Wire Ignition (HWI) configurations.
- IP65 Weather-Rated Enclosure -- Rated IP65 for full protection against dust ingress and resistance to low-pressure water spray from all directions. Suitable for permanent outdoor installation in rain-exposed environments.
- Compact Form Factor -- Measures 2.8 in x 2.8 in x 4 in. Small enough to mount discreetly in a wall, post, or enclosure near the fire feature without requiring a large housing or dedicated electrical panel space.
- High Electrical Rating -- Rated 600VA at 10A, providing reliable performance across the full load range of commercial HPC fire pit systems.
- Three-Circuit Wiring Configuration -- The wiring diagram (from the official HPC spec sheet) shows three independent hot wire in/out pairs (Options 1, 2, and 3) wired in parallel from the 120VAC or 24VAC supply, allowing control of multiple circuits from a single E-Stop installation.
What's Included
INCLUDED IN THE BOX:
- HPC 311-ESTOP-3 Commercial Emergency Stop unit
- Keyed reset key (for supervisor release and restart)
- Mounting hardware
NOT INCLUDED / SOLD SEPARATELY:
- E-Stop Replacement Key (available separately -- part of the E-Stop / Replacement Key option on the product listing; MSRP approximately $65)
- Electrical wiring and conduit (all wiring must be supplied and installed by a certified licensed electrician)
- Compatible HPC Electronic Ignition System (Evolution 360, EI, or HWI -- sold separately) - Junction box or enclosure for mounting (if surface or post-mount installation is required)
INSTALLATION NOTE: The 311-ESTOP-3 is installed on the 120VAC or 24VAC electrical line by a certified licensed electrician. All wiring must comply with local electrical codes. See the official HPC wiring diagram for the 3-circuit wiring schematic showing Hot Wire In / Hot Wire Out for Options 1, 2, and 3. Consult HPC Fire directly for any installation questions: (937) 436-9800 or information@hpcfire.com.
Specifications
Manufacturer: HPC Fire (Hearth Products Controls)
Model / Part Number: 311-ESTOP-3
Product Type: Commercial Emergency Stop Push Button
Category: Fire Pit Safety Accessory
DIMENSIONS:
Size: 2.8 in x 2.8 in x 4 in
ELECTRICAL RATINGS:
Voltage Compatibility: 120VAC or 24VAC (or 12VAC per product title)
Electrical Rating: 600VA, 10A
Wiring Configuration: 3 independent hot wire circuits (Option 1, 2, 3) plus 1 fail-safe function
INGRESS PROTECTION:
IP Rating: IP65 -- fully dustproof; protected against low-pressure water spray from all directions
OPERATION:
Activation: Push button -- single press immediately cuts power to connected circuits
Reset: Keyed release/reset required; system will not restart without key
Restart Authority: Key holder only (supervisor / authorized personnel)
Number of Circuits Controlled: Up to 3 circuits plus 1 fail-safe function
COMPATIBILITY:
Systems: HPC Evolution 360 fire pit control systems; HPC Electronic Ignition (EI) systems; HPC Hot Wire Ignition (HWI) systems
Installation Point: Wired into 120VAC or 24VAC supply line to the HPC burner
SHIPPING:
Ships From: Las Vegas, NV and Dayton, OH (HPC warehouses)
Lead Time: Typically 1 to 2 business days
WARRANTY:
Coverage: HPC Fire standard warranty applies; contact HPC for specific coverage details
Warranty Page: https://hpcfire.com/warranty-information/